The Systec Controls deltaflow DF 25 Averaging Pitot Tube Flow Meter is a multi-point Averaging Pitot Tube flow measuring element developed for measuring gas, liquid and steam flows using the differential pressure (DP) principle. Providing precise and reliable flow measurement with low permanent pressure loss thanks to its special probe profile, the DF 25 can be used with various process media such as steam, compressed air, natural gas, biogas, flue gas, water, oil and benzene. Thanks to options for temperatures from -200 °C to +1240 °C, pressures from -1 to 690 bar and insertion lengths up to 15,000 mm, it can be adapted to heavy industrial applications such as power plants, treatment plants, automotive, iron and steel, chemical and petrochemical.

The system, which can be used together with existing differential pressure transmitters, multivariable transmitters and flow computers, enables mass flow measurement with temperature and pressure compensation. With material options suitable for aggressive and oxidising media, ATEX approved versions, an air purge system for dirty processes and calibration options to PTB standards, it offers a flexible Pitot tube flow meter solution with low pressure loss.

Model
Systec Controls deltaflow DF 25
Type
Multi-Point Averaging Pitot Tube
Medium
Gas / Liquid / Steam
Operating Temperature
-200 °C … +1240 °C
Operating Pressure
-1 … 690 bar
Insertion Length
1 – 15,000 mm
Measuring Principle
Differential Pressure (DP)

Catalogue (Turkish)

You can view the product documentation.

View Document

Catalogue (English)

You can view the product documentation.

View Document

User Guide (Turkish)

You can view the product documentation.

View Document

User Guide (English)

You can view the product documentation.

View Document