The DX-ECAP 101 Capacitive Level Transmitter is a level sensor with a fully insulated probe developed for continuous and precise measurement of the level of conductive liquids in tanks, such as water, glycol, waste water and brine. Operating without moving parts thanks to the capacitive measuring principle, the DX-ECAP 101 detects the change in capacitance between the probe and the tank wall and converts the level information into an analog output signal.

Thanks to its probe length of up to 4 metres, operating pressure of -1 to +25 bar, process temperature of -40 °C to +150 °C, 9–36 VDC supply and standard 2-wire 4–20 mA output, it can be used in various industrial tank applications. With PFA insulation, an IP66/68 housing and ATEX compliance, the DX-ECAP 101 offers a durable, low-maintenance and reliable capacitive level transmitter solution for conductive liquids.

Model
DX-ECAP 101 / 102 / 103 / 107
Type
Capacitive Level Transmitter
Medium to be Measured
Conductive Liquids
Probe Design
Insulated probe / coaxial probe / insulated rope
Maximum Measuring Length
1 m – 32 m depending on model
Operating Temperature
-40 … +150 °C
Operating Pressure
-1 … +25 bar
Standard Output
2-wire 4–20 mA
Power Supply
9 … 36 VDC
Protection Class
IP66 / IP68

Catalogue (Turkish)

You can view the product documentation.

View Document

Catalogue (English)

You can view the product documentation.

View Document

User Guide (Turkish)

You can view the product documentation.

View Document

User Guide (English)

You can view the product documentation.

View Document

CE Certificate (Turkish)

You can view the product documentation.

View Document

CE Certificate (English)

You can view the product documentation.

View Document